Permit: T08CM02020

Parcel: 11901051L


Addresses:

295 W 40TH ST


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T08CM02020

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
08/08/2012 EXCAVATION/LAYOUT REBAR & ZON Approved
08/08/2012 EXCAVATION/LAYOUT REBAR & ZON Partial Approval 1) OK TO PAR TROUGHS ALONG EXTERIOR (ELEC.)
05/11/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. 13-S3.1, 10/S3.1, 12/S3.1, 3/S3.1 - 15 POPOUT FOOTING
EAST AND NORTH BLDG. #5 SOUTH BLDG. #4
2. REBAR & EPOXY SPEEDIE SPECIAL INSPECTED
3. RFI #011 FOR SINGLE 3 5/8 WALL
4. POUR AT OWN RISK - NO APPROVED DRAWINGS REDLINED WITH MRTT ON PLANS USED
04/28/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
6' WING WALL FOOTINGS AT SE CORNER EPOXY BOLT
SPECIAL INSPECTED
04/21/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
INSTALLING EPOXY BOLTS SPEEDIE ON SITE
04/02/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
LAST DUMPSTER FOOTING
03/18/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. SITE WALL FOOTINGS OK TO POUR 30" LAP FOR #5 BARS
2. REMAINING SOUTH DUMPSTER FOOTINGS OK
03/12/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
DUMPSTER ENCLOSURE FOOTING
OK TO POUR
02/25/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
REMAINING LIGHT POLE CAISSONS - OK TO POUR
02/20/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
ALL BUT LAST 4 LIGHT POLE CAISSONS
02/18/2009 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
LIGHTPOLE CAISSONS DENIED
NO CLEARANCE TO DIRT
3" NEEDED PER GENERAL NOTES
12/08/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
OK TO POUR WEST SITE WALL 5' HIGH
PER C.O.T STANDARD DETAIL 109
11/21/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
DOCK POUR BACK OK @ LEVELERS
11/18/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
LOADING DOCK RAMP AS PER FOUNDATION KEYNOTE #9
OK TO POUR
11/17/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
STEM WALLS @ MAIN ENTRY LINES K/2.5-K/3.2; K/4.5-K/5.2
OK TO POUR FOOTINGS
11/14/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
STEM WALL AT NORTH SIDE FOR STEEL STUD WALL S4.1 (11)
11/13/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. DOCK LEVELER STEM WALLS 6 & 7 S4.1 INSPECTED
2. STOREFRONT FOOTINGS OK TO POUR SPECIAL INSPECTED
11/11/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
INCOMPLETE
10/31/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
FOOTING FOR NW DUMPSTER OK TO POUR
10/30/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
LIGHT POLE CAISSONS 13 AS MARKED ON PLAN
10/26/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
12 LIGHT POLE CAISSONS AS MARKED ON PLAN
10/23/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
MAINTAIN 3" CLEARANCE
10/17/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
1. MAINTAIN 3" CLEARANCE, NEEDS SPECIAL INSPECTION
2. #3 TIES 135 HOOK EACH END
10/16/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
SOUTH LOADING DOCK RETAINING WALL
NEEDS ELEC & PLUMBING PRE-SLAB
10/15/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. PARTIAL 1-E TO K -- 5TH LIFT
S1.4 (9) CHORD REINFORCING DETAIL
2. NEED STRUCTURAL STUMPED RFI FOR MISSED CONTROL JOINTS AND ADDED CONTROL JOINTS FOR VERTICAL AND HORIZONTAL REINFORCEMENT
3. SCAFFOLDING NEEDS TO MEET OSHA REQ.
4. SPECIAL INSPECTED
10/14/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
PARTIAL 4 DOCK LEVELER SLABS OK TO POUR
SPECIAL INSPECTED BY SPEEDIE
10/10/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
10/10/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
OK FOR DOCK LEVELERS WHEN JASON M. APPROVES
10/07/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
STEM WALL FOR LOADING DOCK AT BLDG - OK TO POUR

NEEDS SPECIAL INSPECTION
10/02/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
LOADING DOCK FOOTING F4 S1.3 (7) S1.4 (11)
09/30/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. REMAINING F2, F1 COLUMN FOOTING
2. LOADING DOCK F4 WITH P2 NOT CORRECT
CANNOT POUR
09/26/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
7 E TO B3, K 1 TO 3
1. A.5 TO K EXCLUDING POPOUT
2. TOP #5 BAR NOW HAS 35" LAP
3. SPEEDIE SPECIAL INSPECTED
09/25/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
F3, F1, F5, F2 FOOTINGS CMU & COLUMN FOOTINGS
7/E-K
K/3-7

2. SPEEDY SPECIAL INSPECTED
09/22/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. INTERIOR 1 FOOTINGS 34 3/4 BOLTS 12" EMBEDDED
2. SPEEDY SPECIAL INSPECTED
3. PROVIDE ADDRESS AT STREET AND SITE