Inspection History Details
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
Permit Number - T08CM02020
Inspection Description - EXCAVATION/LAYOUT REBAR & ZON
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/08/2012 | EXCAVATION/LAYOUT REBAR & ZON | Approved | ||
| 08/08/2012 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | 1) OK TO PAR TROUGHS ALONG EXTERIOR (ELEC.) | |
| 05/11/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. 13-S3.1, 10/S3.1, 12/S3.1, 3/S3.1 - 15 POPOUT FOOTING EAST AND NORTH BLDG. #5 SOUTH BLDG. #4 2. REBAR & EPOXY SPEEDIE SPECIAL INSPECTED 3. RFI #011 FOR SINGLE 3 5/8 WALL 4. POUR AT OWN RISK - NO APPROVED DRAWINGS REDLINED WITH MRTT ON PLANS USED |
|
| 04/28/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 6' WING WALL FOOTINGS AT SE CORNER EPOXY BOLT SPECIAL INSPECTED |
|
| 04/21/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* INSTALLING EPOXY BOLTS SPEEDIE ON SITE |
|
| 04/02/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* LAST DUMPSTER FOOTING |
|
| 03/18/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. SITE WALL FOOTINGS OK TO POUR 30" LAP FOR #5 BARS 2. REMAINING SOUTH DUMPSTER FOOTINGS OK |
|
| 03/12/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* DUMPSTER ENCLOSURE FOOTING OK TO POUR |
|
| 02/25/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* REMAINING LIGHT POLE CAISSONS - OK TO POUR |
|
| 02/20/2009 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* ALL BUT LAST 4 LIGHT POLE CAISSONS |
|
| 02/18/2009 | EXCAVATION/LAYOUT REBAR & ZON | Denied | IVRS - Inspection : See detailed listing on site.| 999* LIGHTPOLE CAISSONS DENIED NO CLEARANCE TO DIRT 3" NEEDED PER GENERAL NOTES |
|
| 12/08/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK TO POUR WEST SITE WALL 5' HIGH PER C.O.T STANDARD DETAIL 109 |
|
| 11/21/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* DOCK POUR BACK OK @ LEVELERS |
|
| 11/18/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* LOADING DOCK RAMP AS PER FOUNDATION KEYNOTE #9 OK TO POUR |
|
| 11/17/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* STEM WALLS @ MAIN ENTRY LINES K/2.5-K/3.2; K/4.5-K/5.2 OK TO POUR FOOTINGS |
|
| 11/14/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* STEM WALL AT NORTH SIDE FOR STEEL STUD WALL S4.1 (11) |
|
| 11/13/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. DOCK LEVELER STEM WALLS 6 & 7 S4.1 INSPECTED 2. STOREFRONT FOOTINGS OK TO POUR SPECIAL INSPECTED |
|
| 11/11/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* INCOMPLETE |
|
| 10/31/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* FOOTING FOR NW DUMPSTER OK TO POUR |
|
| 10/30/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* LIGHT POLE CAISSONS 13 AS MARKED ON PLAN |
|
| 10/26/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 12 LIGHT POLE CAISSONS AS MARKED ON PLAN |
|
| 10/23/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* MAINTAIN 3" CLEARANCE |
|
| 10/17/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* 1. MAINTAIN 3" CLEARANCE, NEEDS SPECIAL INSPECTION 2. #3 TIES 135 HOOK EACH END |
|
| 10/16/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* SOUTH LOADING DOCK RETAINING WALL NEEDS ELEC & PLUMBING PRE-SLAB |
|
| 10/15/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. PARTIAL 1-E TO K -- 5TH LIFT S1.4 (9) CHORD REINFORCING DETAIL 2. NEED STRUCTURAL STUMPED RFI FOR MISSED CONTROL JOINTS AND ADDED CONTROL JOINTS FOR VERTICAL AND HORIZONTAL REINFORCEMENT 3. SCAFFOLDING NEEDS TO MEET OSHA REQ. 4. SPECIAL INSPECTED |
|
| 10/14/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* PARTIAL 4 DOCK LEVELER SLABS OK TO POUR SPECIAL INSPECTED BY SPEEDIE |
|
| 10/10/2008 | EXCAVATION/LAYOUT REBAR & ZON | Not ready for Inspection | IVRS - Inspection :* | |
| 10/10/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* OK FOR DOCK LEVELERS WHEN JASON M. APPROVES |
|
| 10/07/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* STEM WALL FOR LOADING DOCK AT BLDG - OK TO POUR NEEDS SPECIAL INSPECTION |
|
| 10/02/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* LOADING DOCK FOOTING F4 S1.3 (7) S1.4 (11) |
|
| 09/30/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. REMAINING F2, F1 COLUMN FOOTING 2. LOADING DOCK F4 WITH P2 NOT CORRECT CANNOT POUR |
|
| 09/26/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 7 E TO B3, K 1 TO 3 1. A.5 TO K EXCLUDING POPOUT 2. TOP #5 BAR NOW HAS 35" LAP 3. SPEEDIE SPECIAL INSPECTED |
|
| 09/25/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* F3, F1, F5, F2 FOOTINGS CMU & COLUMN FOOTINGS 7/E-K K/3-7 2. SPEEDY SPECIAL INSPECTED |
|
| 09/22/2008 | EXCAVATION/LAYOUT REBAR & ZON | Partial Approval | IVRS - Inspection :* 1. INTERIOR 1 FOOTINGS 34 3/4 BOLTS 12" EMBEDDED 2. SPEEDY SPECIAL INSPECTED 3. PROVIDE ADDRESS AT STREET AND SITE |