Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T08CM01921
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/01/2009 | FRAMING | Approved | IVRS - Inspection :* | |
04/29/2009 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING VARIOUS PROTECTION PLATES-ON ELECTRICAL AND PLUMBING (BOTH UNITS) 2) PLUMBING MANIFOLD AT WATER HEATER NEEDS TO BE TRIMMED (BOTH UNITS) 3) EXHAUST VENTS, FOR DRYER NEED TO TERMINATE TO EXT. OF BLDG 4) NEED TO FIRESEAL ALL OVERSIZED HOLES IN TOP PLATES |
|
04/06/2009 | FRAMING | Partial Approval | IVRS - Inspection :* 1) INSPECTED 3/4 BOLTS AT METAL STAIRS AND LANDING FOR CONNECTION INTO CMU WALL-OK |