Permit: T08CM01845

Parcel: 138144510

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T08CM01845

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
08/26/2008 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
08/22/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. CORRIDOR WALL TO 16'3" BOND BEAM IN PLACE
2. OK TO POUR BOND BEAM ABOVE SOUTH WINDOW
08/14/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
3RD LIFT OK TO GROUT

NEED RFI FOR BOND BEAM ABOVE WINDOW
DOES REBAR NEED TO BE EPOXIED
REQUIRED AT TOP OF WALL
08/13/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection WORKING ON 3RD LIFT
08/11/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
2ND LIFT OF FIRE REPAIR BOND BEAM IN PLACE
08/08/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
OK TO GROUT 2ND LIFT
08/07/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 1ST LIFT OF FIRE REPAIR
2) EPOXY SPECIAL INSPECTED BY WESTERN TECH
3) CALL IN ELECTRIC INTERMEDIATE
08/05/2008 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. MISSING BOND BEAM AT FLOOR LEVEL
2. A5(7) JOINT MATERIAL SAW CUT
3. PER ARCHITECT NEEDS SPECIAL INSPECTION
4. NEEDS REBAR AT 3 CORNER CELLS
NEW CMU NOTES
5. DEMO PERMIT STILL ACTIVE
6. EXISTING CMU HAS #4 VERTS PLAN CALLS FOR #5's