Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/19/2009 | FRAMING | Approved | IVRS - Inspection :* | |
| 05/06/2009 | FRAMING | Partial Approval | IVRS - Inspection :* 1) EXHAUST DUCT FOR RANGE HOOD NOT AN APPROVED MATERIAL |
|
| 04/27/2009 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO RELOCATE SMOKIES KEEPING 3 FT DISTANCE FROM AIR DUCTS 2) NEED PROTECTION PLATES ON 3" VTR AT BATH 3) NEED TO FIRE SEAL 2 X 4 CHANNEL AT BATHROOM EXT. WALL 4) NEED SLEEVE AND PROTECT HOMERUNS GOING THRU BLOCK WALL 5) NEED TO STRAP AND SUPPORT ALL MECHANICAL DUCT 6) MISSING BLOCK AT BATHROOM FOR INCLUSIVE DESIGN 7) MISSING DUCT FOR DRYER 8) PLANS CALL FOR RANGE HOOD |
|
| 04/21/2009 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 03/19/2009 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |