Permit: T08CM01818

Parcel: 10511061R

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T08CM01818

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
09/17/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
CORRECTIONS MADE OK
OK TO COVER ALL AREAS
09/16/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. COMPLETE INSULATION
2. PROVIDE APPROVED SUPPORT ON BASEMENT OVERHEAD PIPING
09/15/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
09/11/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. POST YOUR STORE NUMBER!
2. CAST IRON MAY NOT BE SUPPORTED BY THE FITTING
3. REQUIRE BRASS FITTING AT CONNECTION TO N/H
4. SUPPORT PIPES VERTICALLY
5. N/H TO BE SUPPORTED WITHIN 18" OF EACH COUPLING
6. USE APPROVED SUPPORTS
7. NO TEST ON GAUGE
8. CLOSET FLANGES TO EXTEND 1/4" ABOVE FINISHED FLOOR
9. THIS MAY NOT BE A COMPLETE LIST
10. CONTINUED "NOT READY" WILL RESULT IN A REINSPECTION FEE