Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T08CM01818
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/17/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* CORRECTIONS MADE OK OK TO COVER ALL AREAS |
|
09/16/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. COMPLETE INSULATION 2. PROVIDE APPROVED SUPPORT ON BASEMENT OVERHEAD PIPING |
|
09/15/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
09/11/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. POST YOUR STORE NUMBER! 2. CAST IRON MAY NOT BE SUPPORTED BY THE FITTING 3. REQUIRE BRASS FITTING AT CONNECTION TO N/H 4. SUPPORT PIPES VERTICALLY 5. N/H TO BE SUPPORTED WITHIN 18" OF EACH COUPLING 6. USE APPROVED SUPPORTS 7. NO TEST ON GAUGE 8. CLOSET FLANGES TO EXTEND 1/4" ABOVE FINISHED FLOOR 9. THIS MAY NOT BE A COMPLETE LIST 10. CONTINUED "NOT READY" WILL RESULT IN A REINSPECTION FEE |