Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/26/2015 | BUILDING - FINAL | Approved | ||
| 03/31/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NOTE 1 FROM PREVIOUS 2) SEWER USE AGREEMENT MAYBE REQUIRED |
|
| 03/24/2009 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) USE COMBINATION, OR WYE WITH 1/8 BEND AT SEWER CONNECTION 2) NEED IN BOTH KITCHENS, 2/20 AMPS CIRCUITS, SMALL APPLIANCE (TYPE) 3) LABEL BOTH A/C UNITS FOR AMPS AND MAX CIRCUIT AMPACITY |
|
| 03/18/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* MAIN HOUSE: 1) COMPLETE GRADING 2) POST UNIT NUMBERS VISIBLE FROM STREET 3) LABEL PLUMBING TYPE DEAD FRONT 4) SITE SEWER SHOWS NEGATIVE PITCH. TRACER WIRE REQUIRED 5) MISSING EXTERIOR LIGHT FIXTURES 6) VACUUM BREAKER HOSE BIBS 7) 2-20 AMP CIRCUITS REQUIRED AT KITCHEN COUNTERS 8) SECURE DISHWASHER DRAIN HOSE HIGHEST POINT UNDER CABINET AIR GAP . 9) SEAL WATER CLOSETS AT BASE 10) WATER HEATER PRESSURE RELIEF TO EXTERIOR ------------------------------------------------------------------------------------------------- GUEST HOUSE: 1) FULL KITCHEN INSTALLED NOT PER PLAN 2) 2-20 AMP SMALL APPLIANCE CIRCUITS REQUIRED IN KITCHENETTE 3) CONNECT WATER HEATER PRESSURE RELIEF TO EXTERIOR 4) GROUND WATER HEATER CONNECTIONS 5) PROVIDE ACCESS TO ATTICS |