Permit: T08CM01797

Parcel: 12009042A


Addresses:

4410 S 4TH AV

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
08/26/2015 BUILDING - FINAL Approved
03/31/2009 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NOTE 1 FROM PREVIOUS
2) SEWER USE AGREEMENT MAYBE REQUIRED
03/24/2009 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) USE COMBINATION, OR WYE WITH 1/8 BEND AT SEWER CONNECTION
2) NEED IN BOTH KITCHENS, 2/20 AMPS CIRCUITS, SMALL APPLIANCE (TYPE)
3) LABEL BOTH A/C UNITS FOR AMPS AND MAX CIRCUIT AMPACITY
03/18/2009 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
MAIN HOUSE:
1) COMPLETE GRADING
2) POST UNIT NUMBERS VISIBLE FROM STREET
3) LABEL PLUMBING TYPE DEAD FRONT
4) SITE SEWER SHOWS NEGATIVE PITCH. TRACER WIRE REQUIRED
5) MISSING EXTERIOR LIGHT FIXTURES
6) VACUUM BREAKER HOSE BIBS
7) 2-20 AMP CIRCUITS REQUIRED AT KITCHEN COUNTERS
8) SECURE DISHWASHER DRAIN HOSE HIGHEST POINT UNDER CABINET AIR GAP .
9) SEAL WATER CLOSETS AT BASE
10) WATER HEATER PRESSURE RELIEF TO EXTERIOR
-------------------------------------------------------------------------------------------------
GUEST HOUSE:
1) FULL KITCHEN INSTALLED NOT PER PLAN
2) 2-20 AMP SMALL APPLIANCE CIRCUITS REQUIRED IN KITCHENETTE
3) CONNECT WATER HEATER PRESSURE RELIEF TO EXTERIOR
4) GROUND WATER HEATER CONNECTIONS
5) PROVIDE ACCESS TO ATTICS