Permit: T08CM01776

Parcel: 123051170

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/08/2008 FRAMING Approved IVRS - Inspection :*
08/07/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NEED TO REPLACE OVER KNOTCHED STUDS ON EAST BEARING WALL OR USE A STUD SHOE, CANNOT BE OVER 40 PERCENT (4 STUDS)
2) WILL NEED PROTECTION PLATES ON ALL ELECTRICAL WIRNG LESS THAN 1 1/4" FROM EDGE OF 2 X 4
3) NEED TO FIRESEAL ALL PENETRATIONS IN TOP PLATE THAT ARE NOT BEING USED
4) OPENING AT GARAGE DOOR-REQUIRES 2 KING STUDS AND 2 JACK STUDS, NEED TO BE ABLE TO VERIFY (1 SEE ONLY 1 JACK STUD)