Permit: T08CM01716

Parcel: 116300130

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T08CM01716

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/26/2010 BUILDING - FINAL Approved IVRS - Inspection :*
03/25/2010 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1) INSTALL 40 W BULBS EXT. LIGHTS PER REVISION
2) NOTE 14 FROM PREVIOUS
03/24/2010 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) RECALL FOR 3/25/10
2) OVER 4" OPENING IN GATE TO POOL
03/23/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO GATE CODE LEFT
03/18/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) EXT. LIGHTS DO NOT MEET LIGHTING CODE
2) EXT. LIGHTS NOT SEALED AT BASE
3) 90 FITTINGS CONDENSATE AND TPR LINES EXTERIOR-PTR COPPER SHALL BE SOLDERED
4) OMIT BREAKFAST BAR OUTLETS COUNTER OVER 6"
5) JACCUZI ACCESS PANEL
6) OMIT OUTLET MASTER SHOWER WITHIN 36" WATER EDGE
7) EXT. MASONRY WALL ADDED TO PERIMETER ON FILL DIRT, ALSO ADDED TO 4' HEIGHT OF RETAINING WALL. PROVIDE ENGINEERED APPROVAL
8) OMIT REAR PORCH FROM PLAN OR BUILD TO PLAN
9) FINAL BARRIER FOR POOL NEEDED ON SEPERATE PERMIT
10) GAS SHUT OFF REQUIRED BEHIND UNION AT POOL HEATER LINE, BY MAIN SHUT OFF TO HOUSE
03/10/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LOWER CLEANOUTS TO GRADE
2) METAL COVERING DRIVEWAY
3) EXT. LIGHTS DO NOT MEET LIGHTING CODE
4) EXT. LIGHTS NOT SEALED AT BASE
5) OVER FUSED CONDENSORS
6) 90 FITTINGS CONDENSATE AND TPR LINES EXTERIOR
7) VACUUM BREAKER HOSE BIBBS
8) OMIT BREAKFAST BAR OUTLETS COUNTER OVER 6"
9) AIR GAP SECURE DISHWASHER DRAIN HOSE HIGHEST POINT
10) HAMMER ARRESTORS LAUNDRY
11) JACCUZI ACCESS PANEL
12) NO POWER MASTER GFCI
13) OMIT OUTLET MASTER SHOWER WITHIN 36" WATER EDGE
14) EXT. MASONRY WALL ADDED TO PERIMETER ON FILL DIRT, ALSO ADDED TO 4' HEIGHT OF RETAINING WALL. PROVIDE ENGINEERED APPROVAL
15) OMIT REAR PORCH FROM PLAN OR BUILD TO PLAN
16) FINAL BARRIER NEEDED POOL
17) PROVIDE 08090 APPROVAL
02/25/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO GATE CODE LEFT
2) ENGINEERING MUST BE FINALED PRIOR TO FINAL APPROVALS