02/24/2009 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
12/24/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* REFER TO DNR CONTACTED MARC AVERY (ENGINEERING) ENGINEERED CHANNEL 9' HAS BEEN COMPROMISED WITH 6' MASONRY WALL AROUND PERIMETER OF HOUSE FILLING IN 9' CHANNEL. CORONADO ENGINEERING AND DEVELOPMENT ENGINEER OF RECORD (622-8041) CONTACTED TROY WILLIAMS. EXISTING RETAINING WALL WITH FILL EAST SIDE COMPROMISED WITH FOOTERS USING EXISTING VALLEY AS CLEANOUT FOR CONCRETE |
|
12/03/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. EXPOSE ALL COLUMN BOTTOM PLATES 2. CHECK NAILING GARAGE ENTRY JOINTS 3. MISSING BLOCKING PER DETAIL 1216 REAR PORCH LEDGER 4. MISSING A34 CLIPS LEDGER REAR PORCH @ MASTER BEDROOM 5. EXPOSE ALL PC88 PORCH HEADERS OR STRAP PER 1416 AND 1316 6. STRAP 6X BEAMS BREAKFAST AND SITTING ROOMS |
|
11/05/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO COVER CLIPS PER DETAILS 8/6 ONLY 2) OK TO POUR REAR PORCH AS BUILT |
|