Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/19/2009 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 02/17/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* DOOR LOCKED NO ACCESS |
|
| 10/16/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
| 10/14/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. WHO INSPECTED DEMO'd PIPING? 2. STILL NEED ARCHITECTS APPROVAL OF REDLINES NO ENGINEERING = NO REVISED PLAN, BUT STILL NEED SOMETHING FROM ARCHITECT/ENGINEER 3. PROVIDE LISTING FOR INSTALLATION OF INVERTED HAMMER ARRESTOR 4. PLUMBER NEEDS TO RECHECK ELEVATIONS ON A-4 FOR PLUMBING -- LOOKS LIKE ROUGH IN IS TOO HIGH FOR EWC WASTE AND URINAL SUPPLY 5. NO PLUMBING HAS BEEN LOOKED AT FOR THE SECOND FLOOR |
|
| 10/13/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1. PROVIDE DRAINAGE FITTINGS AT URINAL AND DOUBLE LAVS. 2. DOUBLE FIXTURE FITTINGS REQUIRED AT BACK TO BACK FIXTURES UPC 204 3. OK TO INSULATE WATER PIPING |