Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08CM01637

Parcel: 141353680

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T08CM01637

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/13/2008 FRAMING Approved IVRS - Inspection :*
08/12/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COIL STRAP 517 DETAIL AT GARAGE 2ND STORY
2) NAIL OFF SHEAR PANELS PER 303/508 DETAIL HOUSE/GARAGE WALL
3) FHA STRAP NEEDED ON OVERNOTCHED TOP PLATE NORTHEAST CORNER
4) SEAL TEAR IN PAPER NORTH WALL NORTHEAST BEDROOM
5) SEAL PENETRATIONS IN CLOSETS 2ND FLOOR EAST WALL
6) FIRESTOP DUCT CHASE CEILING AT TOP OF STAIRS
08/11/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL OFF FHA PLATE ON GARAGE WALL
2) DRAFT STOP FLOOR TRUSSES AT 12" TRUNK LINE
3) DRAFT STOP A-COIL LINE NORTH EAST WALL
4) FIREBLOCK WATER LINES AT CEILING EAST WALL
5) SEAL MAIN WATER LINE PENETRATION AT GARAGE WALL
6) SEAL PENETRATIONS NORTH WALL ABOVE MIDDLE WINDOW
7) NO AIR IN GLYCOL LINE FOR H20 HEATER
8) FHA STRAP NEEDS TO BE NAILED OFF KITCHEN WALL
9) SEAL PENETRATIONS THRU FLOOR TRUSS DRAFT STOP
10) NOT READY-STOPPED INSPECTION