Permit: T08CM01629

Parcel: 114600830

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T08CM01629

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/02/2008 MECHANICAL - FINAL Approved IVRS - Inspection :*
10/01/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. REMOVE ALL FOIL TAPE FROM
FURNACE & WATER HEATER VENTS
2. YOU ARE NOT REQUIRED TO SEAL THESE VENTS.
3. FOIL TAPE IS NOT APPROVED FOR VENT PIPING
4. NEED TO SEE ALL CONNECTIONS
5. PROVIDE MIN. 2" CLEARANCE FROM COMBUSTIBLE AROUND DRYER VENTS AND 1" AROUND FURNACE VENT.
6. PROVIDE INSULATION SHIELD AT FURNACE VENT
7. MARK UNIT DATA PLATE ON AC UNIT
09/26/2008 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
09/24/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
PRIOR CORRECTIONS NOT DONE, REFEE WILL APPLY IF WORK NOT COMPLETE PRIOR TO NEXT INSPECTION
09/12/2008 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
1. DRYER VENTS OK TO COMPLETE
2. PROVIDE MIN. 1" CLEARANCE ON ALL SIDES OF WATER HEATER VENT AT ROOF PENETRATION
3. PROVIDE AN INSULATION SHIELD AROUND WATER HEATER VENT TO KEEP INSULATION AWAY FROM VENT PIPE