Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T08CM01629
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/26/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* SUPPORTING FLEXES DOES NOT SUPPORT THE TANK. WOULD ACCEPT HARD PIPE AS SHOWN ON PLAN ALSO, NO CHECK VALVE INSTALLED MAXI-DRY DRYERS 100,000 BTU |
|
09/24/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CHECK VALVE SHOWN FOR WH 2. SUPPORT T&P DRAIN, PROVIDE AIR GAP, SUPPORT EXP. TANK 3. PROVIDE SEDIMENT TRAPS AT GAS EQUIPMENT 4. SECURE GAS PIPING CLOSE TO VALVE 5. PROVIDE FLEX RATED FOR BTU DEMAND 6. OFFSET PLUMBING VENT TERMINATIONS TO 10' FROM NEWLY INSTALLED COOLER PER NOTE #5 AND UPC REQUIREMENTS. |