Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/09/2008 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* INTERCEPTOR OK WITH INTEGRAL FLOW CONTROL |
|
| 08/26/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* UNDERGROUND SANITARY SYSTEM WATER TEST OK PENDING REVISION FOR DELETION OF HAND SINK GREASE WASTE WATER TEST TO EXTERIOR ONLY OK WILL NEED TEST ON INTERCEPTOR VENT BACK INTO BLD. PIPE WRAPS OK |
|
| 08/25/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* PROVIDE DRAINAGE PER PLAN FOR HAND SINK IN PREP AREA |
|
| 08/20/2008 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. EXPOSE ALL PIPING, PIPING TO BE ON FIRM DRY BEDDING 2. PROVIDE APPROVED LONG RADIUS DRAINAGE FITTINGS AND LONG RADIUS VENT FITTINGS FOR ALL VENTS BELOW FLOOD RIM OF FIXTURE AND DRAINAGES 3. ALL TRAPS REQUIRE THEIR OWN VENT 4. ALL FITTINGS TO BE INSTALLED PER THEIR LISTING 5. INSTALL PER APPROVED PLAN. YOU HAVE THE DEPTH TO CONVENTIONAL VENT THIS SYSTEM PER PLAN LIST MAY NOT BE COMPLETE - HAVE PLUMBER ON SITE AT NEXT INSPECTION |