Permit: T08CM01574

Parcel: 140267290


Addresses:

2395 E CALLE PILCA


Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T08CM01574

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
07/17/2008 FRAMING Approved IVRS - Inspection :*
07/16/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY
07/15/2008 FRAMING Partial Approval IVRS - Inspection :*
1) MOVE PEX 12" FROM CANS
2) SEE ITEMS LEFT
07/11/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. BLK. ALL MECH.
2. WHAT WAS USED FOR PLATE NAILING TO CONCRETE?
3. VERTICAL SURROUND BACKING SHOWER/TUB
4. FINISH CONDENSATE LINES
5. FRONT DOOR BOTTOM PLATE NOT SECURED
6. BEARING PT. FOR TRUSS ANGLE WALL FRONT DOOR
7. AT REAR PORCH 3PT TRUSS REPAIRS HAVE THEY BEEN INSPECTED
8. LOOSE BOTTOM PLATE MSTR. BATH
9. KIT. WINDOW NOT LEVEL/PLUMB
10. PEX TO CANS 12" SEPARATION KIT
11. SHEAR WALL MISSING STUD 16" OC KIT AT REFER
12. CHECK WIRE SIZE RANGE
13. COMPLETE SHEAR TRANSFERS INTERIOR & PLATE ANCHORS