Permit: T08CM01537

Parcel: 12810082B

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T08CM01537

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
12/23/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
08/28/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
ABV CEILING OK
WILL NOT ACCEPT VENT 90 ON URINAL TRAP ARM
08/19/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
GAS TEST DOWN TO 4 PSI
CHECK (SOAP TEST)
OK TO COVER IF HOLDING
FOR GAS CLEARANCE; IDENTIFY AND TEST SYSTEM
AND CORRECT ANY DAMAGED PIPE SUPPORTS.
NEW RTU REQUIRES A SEDIMENT TRAP ON GAS SUPPLY AND PROPER CONDENSATE. HAVE RTU INSPECTED BY MECHANICAL INSPECTOR. WASTE OUTLET FOR URINAL WILL NOT WORK
PROVIDE URINAL CUT SHEET AND CORRECT INSTALLATION
08/15/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
1. T 6-5 REQUIRES 3/4" WATER FOR A URINAL FLUSHOMETER
2. ALSO, URINAL OUTLET SHALL BE THE SAME SIZE AS THE DRAIN ARM
3. DWV TEST THRU ROOF OK, RETEST IF CHANGES ARE MADE ABOVE CEILING
4. NOTE #4 REQUIRES HANGERS NOT CLAMPS.
SUSPEND PIPING FROM STRUCTURE NOT TO IT
5. ABS REQUIRES SUPPORT AT EACH BRANCH CONN., EACH END AND NOT MORE THAN 4' OC
6. BACKING FOR MS FAUCET
7. 3/4 GAS PIPE IN WALL W/9.5PSI OK
8. PROVIDE 10 PSI TEST AND ACCESS TO ROOF