Inspection Status: Approved

Inspection History: ELECTRIC - INTERMEDIATE

Date Description Inspector Results Comments
09/03/2009 ELECTRIC - INTERMEDIATE Approved IVRS - Inspection :*
07/15/2009 ELECTRIC - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INCONDESCENT CLOSET LIGHTS TO BE 100 PERCENT ENCLOSED. BOX TO BE ACCESSIBLE IS BURRIED BEHIND SHEETROCK. NEED CLEARANCE TO SHELF STORAGE PER NEC 410
2) EQUIPMENT GROUNDS TO BE SPLICED TOGETHER WITH CRIMPS OR WIRE NUTS
3) CANNOT ATTACH PLASTIC BOXES WITH METAL SCREWS ON INSIDE OF BOX USED OLD WORK BOXES OR ATTACHMENT MEANS TO BE OUTSIDE OF BOX
4) CANNOT RUN ROMEX OUTSIDE UNDER EVE FOR OUTSIDE LIGHTS USE UF CABLE OR RACEWAY
5) SEAL UNUSED OPENINGS IN PLASTIC BOXES
6) CANNOT SEE NEW WIRING ADDITION HAS BEEN SHEETROCKED AND FINISHED
7) OUTDOOR RECEPTACLES TO BE GFI PROTECTED