Date Description Inspector Results Comments
07/29/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/24/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HGUS 26 2 NEEDED FOR 2 PLY RAFTER ABOVE STAIRWELL
2) STUD SHOE NEEDS PROPER FASTENING
3) FINISH STUCCO MESH
4) LINE SET TO SHORT TO FAN UNIT IN ATTIC
5) MOVE DUCT ABOVE ATTIC ACCESS
06/27/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
EPOXY ANCHORS NEEDED AT INTERIOR SHEAR WALL