Permit: T08CM01499

Parcel: 137084750

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
07/16/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/15/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL PROTECT PLUMBING AT EXTERIOR WALLS WITHIN 1 1/2" PLATES EDGE EXTERIOR
06/20/2008 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) CANCELLED PER CONTRACTOR
06/19/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NUMBER 3 AND 4 FROM PREVIOUS INSPECTION NEED REVISION WITH CITY APPROVAL
2) ANCHOR BOLTS STILL NEEDED
06/18/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING ANCHORS BOLTS ON SHEAR PANEL PER SHEAR SCHEDULE
2) DETAIL 9/S3.1 NOT FOLLOWED-NEED GABLE BRACING
3) DETAIL 7/S3.1 CALLS FOR 1/2 PLYWOOD AT OVERHANGS
4) TRUSSES NOT LAYED OUT PER TRUSS PLAN-REVISE PLAN WITH CITY APPROVAL OR RUN LIKE PLAN SAYS