Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T08CM01497

Parcel: 133230590


Addresses:

7371 E CALLE MERIDA

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/01/2011 FRAMING Approved IVRS - Inspection :*
11/22/2010 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NEED ALL INTERMEDIATES COMPLETED WITH THIS INSPECTION
05/26/2010 FRAMING Partial Approval IVRS - Inspection :*
1) GO AHEAD PUT ROOF STRUCTURE ON, INCLUDING ROOF DECK
2) YOU NEED H2.5 SIMPSON OR EQUAL METAL TIES, STUD TO BOTTOM PLATE, STUD TO TOP PLATE, RAFTER TO TOP PLATE, YOU CAN PUT THEM ON THE INSIDE OR OUTSIDE OF WALL
3) YOU NEED A BOLTS AT 6' 0" ON CENTER, 12" IN FROM EVERY JOINT
4) CONTINUE ON LOOKS GOOD