Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/14/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 12/30/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) CLEANOUTS REQUIRE 12" CLEAR IN FRONT 2) INSTALL CLIPS ON FRONT OF 1ST FLOOR SINK 3) FIRST FLOOR WATER HEATER REQUIRES SHUT OFF VALVE IN ACCESIBLE LOCATION |
|
| 12/09/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* HAVE PLAN & PERMIT ON SITE NOTE: WATER HEATER T&P DRAIN TO BE FULL SIZE RIDGID PIPING WITH GRAVITY DRAINAGE. DISHWASHER TO HAVE CLAMP AT HIGH LOOP FOR DRAINAGE. PROVIDE CORRECT DRAINAGE AT LAVS. LIST MAY NOT BE COMPLETE. |