Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T08CM01394
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/04/2008 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
09/02/2008 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED POST TENSION TAG ON WATER LINE 2) MARK PANEL NON METALIC PLUMBING 3) INSTALL GAS DRYER OR REMOVE FLEX AND CAP VALVE 4) INSTALL SECONDARY DRAIN OR CUT OFF SWITCH ON A/C 5) RAISE VENT ON CONDENSATE DRAIN ABOVE SWITCH OR 2ND DRAIN |