Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T08CM01355

Parcel: 13219049E


Addresses:

2833 E MISSOURI ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
12/04/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/18/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO DRY IN
2) COMPLY WITH DETAILS 1/6, 6/6, 2/62 H2.5 EACH TRUSS
3) PROVIDE 42" FOR DELETION 2 POINT BEARING TRUSSES A39, A40 TRUSSES
4) NAIL PROTECT PLUMBING
5) CHECK ALL B BRACE PANELS 2 EACH ABS
6) COMPLY WITH REAR PORCH DETAIL 2 H2.5 EACH TRUSS 3/11
11/17/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
11/14/2008 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NAIL OFF EXISTING SHEATHING
2) CUT VIEW HOLES-TOP AND BOTTOM OFF COLUMNS AND FINISH ROOF
3) RECALL
11/10/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) PARAPETS OK TO COVER WITH SHEAR