Permit: T08CM01353

Parcel: 132180910


Addresses:

1209 E KENTUCKY ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/05/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/23/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAILING SIDING 6" ON CENTER AT EDGES
2) 6" CLEARANCE REQUIRED FROM WATER HEATER VENT FROM COMBUSTIBLE 2" CLEARANCE FOR DBL VENT
3) PROTECT ALL ROMEX LESS THAN 8' FROM FLOOR
4) 10-3 WITH GROUND REQUIRED FOR DRYER WIRE
5) ADD 2 X 4 UNDER ROOF RAFTERS AS INDICATED
5) SILL SIDING AT SLAB WITH SILICONE