Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/15/2008 | FRAMING | Approved | IVRS - Inspection :* | |
| 08/07/2008 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NEED 1 HOUR FIRE RATING DETAIL FOR SOFFITS ON WEST SIDE |
|
| 08/06/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL ALL DOORS AND WINDOWS 2) NAIL PROTECT SOLAR LINES AT TOP PLATE IN GARAGE 3) BOLTS NEEDED IN RETRO HOLDOWNS IN GARAGE 4) MIN. PLATFORM DISTANCE NEEDED IN FRONT OF MECHANICAL IN ATTIC 5) SEAL TAR PAPER BEHIND UPSTAIRS MASTER BATH VANITY 6) NAIL PROTECT LOW VOLTAGE ABOVE SMART PANEL |
|
| 08/05/2008 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER RON |