Date Description Inspector Results Comments
07/09/2008 FRAMING Approved IVRS - Inspection :*
07/08/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
CANCELED PER RON
07/07/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. DRAFT STOP UNDER 2ND FLOOR TUBS
2. FHA STRAP NEEDED IN NOTCHED 2X4 GARAGE WALL
3. SHIM FULL 3 1/2" ON BEARING OF FLOOR TRUSSES ON GARAGE WALL
4. FINISH STUCCO SOUTH SIDE OF HOUSE
5. DRAFT STOP AROUND 3" BY GARAGE SERVICE DOOR TO HOUSE
6. FINISH STUCCO AROUND PATIO DOOR
7. WINDOWS NOT ALL IN
8. FIRESTOP DUCT CHASE 2ND FLOOR CEILING
9. DISPERSE GYPSUM PER MANUFACTURES OF FLOOR TRUSSES
10. WIRES AGAINST GUSSETS IN GARAGE TRUSSES
11. HOOK UP FAN IN BATH UPSTAIRS
12. NAIL PROTECT 2" VENT MAIN FLOOR BATH TOP PLATES

STOPPED INSPECTION