Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T08CM01287
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/09/2008 | FRAMING | Approved | IVRS - Inspection :* | |
07/08/2008 | FRAMING | Not ready for Inspection | IVRS - Inspection :* CANCELED PER RON |
|
07/07/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. DRAFT STOP UNDER 2ND FLOOR TUBS 2. FHA STRAP NEEDED IN NOTCHED 2X4 GARAGE WALL 3. SHIM FULL 3 1/2" ON BEARING OF FLOOR TRUSSES ON GARAGE WALL 4. FINISH STUCCO SOUTH SIDE OF HOUSE 5. DRAFT STOP AROUND 3" BY GARAGE SERVICE DOOR TO HOUSE 6. FINISH STUCCO AROUND PATIO DOOR 7. WINDOWS NOT ALL IN 8. FIRESTOP DUCT CHASE 2ND FLOOR CEILING 9. DISPERSE GYPSUM PER MANUFACTURES OF FLOOR TRUSSES 10. WIRES AGAINST GUSSETS IN GARAGE TRUSSES 11. HOOK UP FAN IN BATH UPSTAIRS 12. NAIL PROTECT 2" VENT MAIN FLOOR BATH TOP PLATES STOPPED INSPECTION |