Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM01283
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/05/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
06/04/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 2 CLIPS PER POST AT TOP AND BOTTOM PLATES PER #15 IN NOTES 2) NAIL OFF POSTS 2 NAILS PER 12" ON CENTER PER NOTES #13 3) RENAIL STAIRWAY SHEAR FOR SHINGERS 4) 2 NAILS IN BOTTOM PLATES FOR LET IN BRACE SOUTH SIDE 5) BOTTOM CHORD GABLE END RAFTER SOUTH SIDE NAILED OFF PER DETAIL 6) NAIL OFF SHEAR PANELS TO BOTH STUDS WITH HOLDOWNS 7) RENAIL SHEAR PANELS IN GARAGE WHERE SHINERS MISSED STUDS 8) TRUSS FIX FOR BROKEN FLOOR TRUSS ABOVE KITCHEN |