Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08CM01283

Parcel: 141350920

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM01283

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/05/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/04/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 2 CLIPS PER POST AT TOP AND BOTTOM PLATES PER #15 IN NOTES
2) NAIL OFF POSTS 2 NAILS PER 12" ON CENTER PER NOTES #13
3) RENAIL STAIRWAY SHEAR FOR SHINGERS
4) 2 NAILS IN BOTTOM PLATES FOR LET IN BRACE SOUTH SIDE
5) BOTTOM CHORD GABLE END RAFTER SOUTH SIDE NAILED OFF PER DETAIL
6) NAIL OFF SHEAR PANELS TO BOTH STUDS WITH HOLDOWNS
7) RENAIL SHEAR PANELS IN GARAGE WHERE SHINERS MISSED STUDS
8) TRUSS FIX FOR BROKEN FLOOR TRUSS ABOVE KITCHEN