| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/13/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 06/12/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING NAILS ON ROOF 2) BLK ALL BRACE PANEL EDGES 3) NEED A35 ON HEADER (BEARING WALL) CONNECTION TO BEARING STUDS 4) NEED MORE NAILS ON 2 X 10 (LAP) RAFTERS AT INTERIOR BEARING WALL |