Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T08CM01216
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/07/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) PLUMBING FINAL OK |
|
08/04/2008 | PLUMBING - FINAL | Not ready for Inspection | CLEAN BACTERIA REPORT INSULATE HOT HEAT TRAPS AT WH |
|
08/01/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. UNDERGROUND PIPING IS TO BE SCOTCHCOAT 2. TAPING IS LIMITED TO FITTINGS AND MARRED PIPE 3. THE CORRECT TAPING METHOD IS HALF OVERLAP DOUBLE WRAP 4. YOU DO NOT HAVE PERMISSION TO OCCUPY! |
|
06/30/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* PLASTIC PIPING SHALL CONFORM WITH ASTMD2513 STD. SPECS FOR THERMOPLASTIC GAS PRESSURE PIPE, TUBING AND FITTINGS. PIPE TO BE USED SHALL BE MARKED "GAS" AND ASTM2513 |