Permit: T08CM01216

Parcel: 99999999A


Addresses:

4545 N VIA ENTRADA


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08CM01216

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/07/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
1) PLUMBING FINAL OK
08/04/2008 PLUMBING - FINAL Not ready for Inspection CLEAN BACTERIA REPORT
INSULATE HOT
HEAT TRAPS AT WH
08/01/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. UNDERGROUND PIPING IS TO BE SCOTCHCOAT
2. TAPING IS LIMITED TO FITTINGS AND MARRED PIPE
3. THE CORRECT TAPING METHOD IS HALF OVERLAP
DOUBLE WRAP
4. YOU DO NOT HAVE PERMISSION TO OCCUPY!
06/30/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
PLASTIC PIPING SHALL CONFORM WITH ASTMD2513
STD. SPECS FOR THERMOPLASTIC GAS PRESSURE PIPE, TUBING AND FITTINGS. PIPE TO BE USED SHALL BE MARKED
"GAS" AND ASTM2513