Permit: T08CM01216

Parcel: 99999999A


Addresses:

4545 N VIA ENTRADA


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T08CM01216

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/02/2008 ELECTRIC - FINAL Approved IVRS - Inspection :*
06/30/2008 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. REVISE PERMANENT PANEL DIRECTORY SO IT IS CORRECT AND LEGIBLE
2. MULTI-WIRE (BRANCH CKT WITH SHARED NEUTRAL) TO WASHER RECEPTACLES TO TERMINATE ON SEPARATE PHASES
3. MULTI-WIRE CKT TO SINGLE DEVICE YOKE REQUIRES
A 2-POLE BREAKER
4. PIGTAIL NEUTRALS TO SPLIT-WIRED WASHER RECEPTACLE