Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM01204
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/19/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
06/13/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST TO BEAM CONNECTION PER 5A & B SHEET DT1 2) INTERIOR SHEAR TRANSFER BROUGHT TO BOTTOM CHORD AT SHEAR WALL IN KITCHEN DINING 3) H2.5 RAFTER HEELS TO BEAM ABOVE FRONT DOOR 4) NAIL PROTECT BOTTOM PLATES FOR PIPES AND CONDUIT |