Permit: T08CM01197

Parcel: 141387190

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM01197

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/20/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
06/19/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PIN SHEAR WALLS AT INTERIOR WALLS PER PLAN
2) MINIMUM 22" WIDE ACCESS IN ATTIC TO MECHANICAL
3) TOP AND BOTTOM PLATES IN MASTER TOILET ROOM
06/02/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) INTERIOR HOLDOWNS NEEDED
05/30/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RSP4'S NEEDED KING STUDS 32" ON CENTER
2) STRAP HEADER EAST SIDE
3) SHEAR PANEL MISSING WEST SIDE
4) NAIL BOTTOM CHORD OF GABLE END RAFTERS PER PLAN
5) NAIL PROTECT PIPES AT BOTTOM PLATES
6) HOLDOWNS AND ANCHORS THROUGHOUT
05/29/2008 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
- ANCHOR BOLTS THROUGHOUT
- MISSING SHEAR PANEL AT BACK OF HOUSE
- MISSING SHEAR PANEL EAST SIDE OF HOUSE
05/27/2008 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) HEADER NEEDED AT EXTERIOR WALL AT FRONT
2) 405 DETAIL AT BACK OF HOUSE
3) A34'S NEEDED AT GABLE BRACING
4) H2.5'S NEEDED EACH RAFGTER ABOVE FOYER
5) CLIP STUDS 32" ON CENTER AT EXTERIOR
6) PANELS NEEDED FOR 475 DETAIL AT FRONT ENTRY
7) STILL WORKING-STOPPED INSPECTION