Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM01194
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/10/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
06/09/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) ANCHOR BOLTS FROM PREVIOUS INSPECTION |
|
06/06/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 2 RSP AT TOP AND BOTTOM PLATES AT POST WEST GARAGE WALL 2) RETRO OR FIX STRAP AND NAIL INTO STUDS AT SOUTH EAST SHEAR PANEL STHD8 WHERE NAILS GO BETWEEN TRIMMER AND KING STUD 3) 1/2" ANCHOR BOLTS 12" ON CENTER FOR #6 SHEAR AT BACK OF GARAGE 4) PINS 6" ON CENTER DBL #1 SHEAR IN LIVING ROOM 5) 4-2 X 4 POST ON SIDE OF GARAGE SERVICE DOOR WEST WALL |
|
06/04/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection |