Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T08CM01176
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/05/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
06/19/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* - EJECTOR PUMP UNDER SINK SHALL BE SHOWN ON APPROVED PLAN - EJECTOR REQUIRES AN ALARM ALSO, CHECK VALVE AND GATE VALVE - PROVIDE A DETAIL FOR INSTALLATION - ALSO, CORRECT USE OF FITTINGS REQUIRED - SANITARY TEES AND CLEANOUT TEES ARE TO BE INSTALLED VERTICALLY AND DON'T LINK WATER FLEXES TOGETHER. |