Permit: T08CM01111

Parcel: 11615190K

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T08CM01111

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
12/18/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
FLANGES OK
12/12/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
CLOSET FLANGES OK ALL EXCEPT FOR RM.110
CORRECT MAKE UP ON FITTING
09/16/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
PLUMBERS TAPE NOT APPROVED STRAP
SUPPORT TRAP ARM
WATER TEST ON DWV OK
NEED TO SEE CLOSET FLANGES
09/12/2008 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
1. ABS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION
OR ELEVATION AND AT THE END OF BRANCHES THEN
EVERY FOUR FEET
2. SUPPORT VERTICAL PIPING
SUPPORT HORIZONTAL PIPING
3. PROTECT ABS FROM METAL STUD
4. CAP OFF ALL OPEN PIPING
5. SUPPORT STUB-OUTS
SUPPORT TRAP ARMS
6. IF ROUGH SOIL INSPECTION DOES NOT SAY TESTED
THRU ROOF - RETEST ABS