Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/18/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* FLANGES OK |
|
| 12/12/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGES OK ALL EXCEPT FOR RM.110 CORRECT MAKE UP ON FITTING |
|
| 09/16/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* PLUMBERS TAPE NOT APPROVED STRAP SUPPORT TRAP ARM WATER TEST ON DWV OK NEED TO SEE CLOSET FLANGES |
|
| 09/12/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1. ABS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES THEN EVERY FOUR FEET 2. SUPPORT VERTICAL PIPING SUPPORT HORIZONTAL PIPING 3. PROTECT ABS FROM METAL STUD 4. CAP OFF ALL OPEN PIPING 5. SUPPORT STUB-OUTS SUPPORT TRAP ARMS 6. IF ROUGH SOIL INSPECTION DOES NOT SAY TESTED THRU ROOF - RETEST ABS |