Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T08CM01111
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/19/2008 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* DELETE SINK IN MGR's OFFICE OK TO COVER UNDERGROUND |
|
| 07/30/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | 1. OK TO BACKFILL RESTROOM #150 WITH CLEAN FILL 2. PUBLIC RESTROOM #105 - PIPE COVERED WITHOUT INSPECTION 3. RESTROOM #130 NO NEW WORK BEING DONE AT THIS TIME PULL AND REPLACE ONLY |
|
| 07/29/2008 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection :* 4" BRANCH PIPING REQUIRES A FULL SIZE CLEANOUT |
|
| 07/24/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* P-4 FOR 147 OK TO COVER RESTROOM #145 ABS THRU ROOF OK WATER TEST OK ABS UNDERGROUND FOR #138, 140, 141 & 142 OK TO COVER ABS UNDERGROUND THRU ROOF FOR #135 OK TO COVER ROOM #135 FLOOR SINK OK TO COVER |
|
| 07/11/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* UNDERGROUND CAPS ON DEMO PLUMBING FOR NORTH ALL UNITS OF CORRIDOR 143 OK DWV WATER TEST NORTH OF CORRIDOR 143 ALL UNITS THRU ROOF OK REDLINE OF B-4 ANTE ROOM 123 ON SITE PIPE WRAPS THIS AREA OK |