Permit: T08CM01097

Parcel: 129091670


Addresses:

1820 S CHERRY AV

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
09/29/2008 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
09/24/2008 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FOOTING SHALL BE 12" WIDE MINIMUM, INTERIOR, EXTERIOR 12" BELOW GRADE, SEE APPROVED DRAWING
2) REBAR SHALL BE ELEVATED 3" FROM EARTCH
3) PROVIDE 12" X 12" CONCRETE PIER AT PORCH N.W. CORNER
4) PROVIDE 8" X 8" TOE DOWN AT PORCH NORTH SIDE
09/02/2008 EXCAVATION/LAYOUT REBAR & ZON Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) RAISE REBAR OFF OF BOTTOM OF FOOTING-OTHERWISE OK