Permit: T08CM01075

Parcel: 116274640

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/02/2009 FRAMING Approved IVRS - Inspection :*
12/30/2008 FRAMING Partial Approval IVRS - Inspection :*
1) PARTIAL UNTIL WINDOW IS REMOVED FOR OPENING INTO OFFICE
12/11/2008 FRAMING Partial Approval IVRS - Inspection :*
1) UNTIL ALL INTERMEDIATES ARE APPROVED
12/05/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BUILT UP ROOF TO CREATE VALLEY TO SCUPPER OVER GARAGE NOT NAILED DOWN
2) ANCHOR BOTTOM PLATES WITHIN 12" OF ALL ENDS OF SILL PLATES
3) NAIL OFF INSIDE CORNER OF SHEATHING BY EXISTING BOTTOM 3' OUTSIDE SHEATHING
4) NAIL OFF OUTSIDE CORNER OF 45 DEGREE WALL BELOW WINDOW SILL HEIGHT