Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T08CM01067
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/10/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS SUBJECT TO HEALTH DEPT PLAN |
|
07/09/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | 1. VENTING BELOW FLOOD RIM, HORIZONTALLY LIMITED TO STRUCTURAL CONDITIONS 2. OK TO INSULATE HOT 3. NEED TO SEE TEST ON ABS 4. GAS OK |
|
07/03/2008 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* WHERE A VENT CONNECTS TO A HORIZONTAL DRAIN, IT SHALL HAVE ITS INVERT TAKEN OFF ABOVE THE DRAINAGE CENTER LINE, DOWNSTREAM OF THE TRAP BEING SERVED. EACH VENT SHALL RISE VERTICALLY, TO A POINT NOT LESS THAN 6" ABOVE THE OVERFLOW BEFORE OFFSETTING HORIZONTALLY ALL VENT FITTINGS INSTALLED BELOW FLOOD RIM TO BE DRAINAGE TYPE (SWEEPS AND COMBOS) ABS TO BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION AND AT THE END OF BRANCHES, THEN NO MORE THAN 4' BETWEEN HANGERS. |
|
06/26/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* |