Permit: T08CM01065

Parcel: 12217284A

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08CM01065

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/08/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
09/03/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. DISHWASHER HOSE TO BE SECURED WITHIN 2" OF DRAIN BOARD HEIGHT
2. CLEANOUTS REQUIRE 12" CLEAR IN FRONT
3. T&P RELIEF DRAIN TO BE GRAVITY TYPE
08/29/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. PAINT VENTS THRU ROOF
2. HAVE WATER ON TO ALL FIXTURES
3. ALL HOSE BIBS REQUIRE VACUUM BREAKERS
4. ALL NEW WATER HEATERS REQUIRE RIDGID APPROVED TEMPERATURE AND PRESSURE RELIEF DRAIN PIPING, GRAVITY DRAIN TO DAYLIGHT TERMINATING 6" TO 24" AT
90 DEG. DOWN FROM FINISH GRADE
5. PROVIDE FULL SIZE 3/4" BRANCH TAILPIECE CONNECTION FOR CONDENSATE DRAIN
6. PROVIDE CLAMP AT HIGH LOOP OF DISHWASHER
DRAIN HOSE