Permit: T08CM01055

Parcel: 141096410

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/11/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
CS STRAPS 15" ABOVE AT FRONT
ITEM 3
06/05/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) BAD STUD IN GARAGE SOUTH WALL MARKED BLACK
2) MIN 2 A.B.'S
2) SEE SHEAR PLAN 1/2 DIAMETER SHEARWALL BOTTOM PLATE FRONT REAR WALL
3) F STRAPS AT FRONT ONE AT STAIR 1ST AND 2ND FLOOR
4) H.D.'S AT GARAGE TO HOUSE A LTT20B HTT16'S INSTALLED
5) FRONT ROOF TRUSS A11E 3 PT BEARING
6) NO JOB CARD