Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08CM01042

Parcel: 14027050D

Inspection Status: Approved

Inspection History: SITE - SEWER

Permit Number - T08CM01042

Inspection Description - SITE - SEWER

Inspection Status - Approved

Date Description Inspector Results Comments
08/18/2008 SITE - SEWER Approved IVRS - Inspection :*
08/13/2008 SITE - SEWER Not ready for Inspection IVRS - Inspection :*
1. INSTALL PER APPROVED PLANS
2. INSTALL PER KEYNOTES #182
3. PROVIDE UNIFORM FALL ON ALL PIPING WITH VERIFICATION OF GRADE
4. PROVIDE 12" COVER ON SDR35 OR PROVIDE MATERIAL APPROVED FOR INSIDE OF BUILDING USE
5. PROVIDE APPROVED TRANSITION FOR ALL TRANSITION
6. LIST MAY NOT BE COMPLETE
7. HAVE SITE SEWER CONTRACTOR ON SITE FOR INSPECTION