Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T08CM01037
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/06/2008 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* | |
| 09/04/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1. ROUGH SOIL & BELOW SLAB WATER INSTALLED PER REDLINES. 2. PRE-SLAB PROTECTION OK 3. OK TO COVER SUBJECT TO PLAN REV. 4. PLAN SPECS. DO NOT SPECIFY NFPA REQUIRMENTS FOR AIR AND VACUUM SYSTEMS |
|
| 08/14/2008 | PLUMBING - ROUGH, SOIL | Partial Approval | IVRS - Inspection :* 1. BELOW SLAB DRAINAGE PIPING W/WATER TEST OK EXCEPT AT FIXTURES P-8 2. THE BELOW FLOOR TRAP ARM, TRAP AND TAILPIECE FOR FIXTURES P-8 ARE IN VIOLATION OF UPC SECTIONS 1001.4, 1003.3 AND T 7-3 3. THE CASCADE DENTAL CHAIRS WITH CUSPIDOR AND HANDPIECE APPEAR TO BE IN VIOLATION OF UPC 301.1.1, 603 AND T 7-3, BASED ON THE INFORMATION PROVIDED AT THIS TIME. 4. PROVIDE LISTINGS REQUIRED BY 301.1.1 AND UPC COMPLIANT PIPING CORRECTIONS |
|
| 08/13/2008 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* ALBERTS PLUMBING, DAVID WITH EGLIN/COHEN ARCHITECTS |