Permit: T08CM01037

Parcel: 12703514B


Addresses:

5747 E 5TH ST


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T08CM01037

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
11/06/2008 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
09/04/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1. ROUGH SOIL & BELOW SLAB WATER INSTALLED PER REDLINES.
2. PRE-SLAB PROTECTION OK
3. OK TO COVER SUBJECT TO PLAN REV.
4. PLAN SPECS. DO NOT SPECIFY NFPA REQUIRMENTS FOR AIR AND VACUUM SYSTEMS
08/14/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
1. BELOW SLAB DRAINAGE PIPING W/WATER TEST OK EXCEPT AT FIXTURES P-8
2. THE BELOW FLOOR TRAP ARM, TRAP AND TAILPIECE FOR FIXTURES P-8 ARE IN VIOLATION OF UPC SECTIONS 1001.4, 1003.3 AND T 7-3
3. THE CASCADE DENTAL CHAIRS WITH CUSPIDOR AND HANDPIECE APPEAR TO BE IN VIOLATION OF UPC 301.1.1, 603 AND T 7-3, BASED ON THE INFORMATION PROVIDED AT
THIS TIME.
4. PROVIDE LISTINGS REQUIRED BY 301.1.1 AND UPC COMPLIANT PIPING CORRECTIONS
08/13/2008 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
ALBERTS PLUMBING, DAVID WITH EGLIN/COHEN ARCHITECTS