Inspection History Details
Inspection Status: Approved
Inspection History: SITE - SEWER
Permit Number - T08CM01026
Inspection Description - SITE - SEWER
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/31/2008 | SITE - SEWER | Approved | IVRS - Inspection :* | |
07/25/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* AIR TEST ON PIPING THAT HAS BEEN RE-WORKED FROM 1' FROM BUILDING STUBOUTS THRU CLEANOUTS INTO MANHOLE OK - HAVE LICENSED SURVEYOR OR ENGINEER VERIFY GRADE FOR FALL ON PIPING. HAVE PIMA COUNTY OK PRIOR TO HCS CONNECTION |
|
07/22/2008 | SITE - SEWER | Partial Approval | IVRS - Inspection :* 6" SDR AIR TEST FROM END OF LINE WITH (2) 4" HCS LATERALS TO 30' FROM NEW MANHOLE PIPING WILL REQUIRE VERIFICATION OF GRADE BY LICENSED SURVEYOR OR ENGINEER. WITH OK FROM ENGINEER OF RECORD FOR LESS THAN 1% FALL ON PIPING. COMPLETION & RETEST REQUIRED WITH HCS LATERAL EXPOSED AT TIME OF TIE IN |
|
07/18/2008 | SITE - SEWER | Not ready for Inspection | IVRS - Inspection :* 1. TEST NOT HOLDING 2. PROVIDE CITY APPROVED PLAN ON SITE FOR ALL CHANGES |