Permit: T08CM01016

Parcel: 128140630


Addresses:

5232 E 18TH ST

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
08/22/2008 MECHANICAL - FINAL Approved IVRS - Inspection :*
08/20/2008 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
REMOVE ALL FOIL TAPE FROM VENT CONNECTORS.
PVC CANNOT BE WITHIN 6" OF FURNACE VENT CONNECTOR.
USE COPPER AS NEEDED.
PROVIDE PRIMER ON ALL PVC FITTINGS PRIOR TO GLUE.
BUILD TRAP PER INSTALL INSTRUCTIONS.
PROVIDE OVERFLOW SENSOR ON SECONDARY DRAIN.
CLOSET DOORS NEED TO CLOSE TIGHT.
LOW VOLTAGE WIRE OUTDOORS MUST BE PROTECTED FROM DAMAGE.
PROVIDE A ROMEX CONNECTOR ON FURNACE POWER CORD.