Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/18/2008 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* OK FOR SHEETROCK |
|
| 07/16/2008 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* PROVIDE VENT PIPE FOR WATER HEATER AND INSULATION SHIELDS AROUND FURNACE AND WATER HEATER VENTS. EXTEND VENT PIPES MIN. 2' ABOVE COMBUSTION AIR INTAKE |
|
| 07/15/2008 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. SUPPORT DUCT PER PLANS AS NEEDED 2. PROVIDE PROPER RADIUS IN FLEX DUCT BEND 1X 3. INSULATE RETURN PLENUM PER PLANS 4. CROSS BLOCK BOOT BOXES TO PROVIDE A SQUARE OPENING 5. PANDUITS ARE NOT TO BE USED AS DUCT SUPPORT |