| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/22/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* RECEIVED BACTERIA REPORT FOR POTABLE WATER SYSTEM |
|
| 08/20/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* CALL IN 03050 WITH 03090 INSPECTION 1. PAINT VENTS THRU ROOF FOR SUN EXPOSURE 2. MAKE ALL FIXTURES WATER TIGHT 3. EXPOSE CLEANOUTS AT LAUNDRY BOX AND VENT FOR FLOOR DRAIN AND P-2 AT ADA LAV 4. PROVIDE VACUUM BREAKERS AT HOSE BIBS AT P-8 5. COMPLETE INSULATION AT HOT & HOT RETURN PIPING AT WATER HEATER NOTE: HAND HELD SHOWER CANNOT FALL INTO SUBMERGED SHOWER DRAINAGE WITHOUT CORRECT BACKFLOW PROTECTION. HAVE BACTERIA REPORT ON SITE. |