Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/07/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 08/05/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* CLOSET FLANGES OK COMPLETE SHOWER PAN & 125# PRESSURE RELIEF MALE ADAPTOR |
|
| 07/15/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* NEED TO SEE CORRECT FLANGES & SHOWER PAN WITH MALE ADAPTOR FOR 125# PRESSURE RELIEF FOR ALT. FORM OF T&P |
|
| 07/14/2008 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DWV WATER TEST THRU ROOF OK WATER DISTRIBUTION OK EXCEPT 1. PROVIDE 18" MINIMUM COPPER PIPING IN WALL AT WATER HEATER 2. 2006 IECC REQUIRES MINIMUM 8' IN AND 8' OUT OF WATER HEATER PIPING TO BE INSULATED 3. INSTALL WATER HAMMER ARRESTORS PER PLAN 4. PROVIDE STAMPED SEALED LETTER FROM ENGINEER OR ARCHITECT GIVING OK TO SUP PEX WATER PIPING FOR T/L COPPER PER PLAN 5. NEED TO SEE CORRECT SHOWER PAN INSTALL AND CLOSET FLANGE AFTER FINISH FLOOR INSTALL |