Permit: T08CM01016

Parcel: 128140630


Addresses:

5232 E 18TH ST

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/07/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
08/05/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
CLOSET FLANGES OK
COMPLETE SHOWER PAN & 125# PRESSURE RELIEF MALE ADAPTOR
07/15/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
NEED TO SEE CORRECT FLANGES & SHOWER PAN WITH MALE ADAPTOR FOR 125# PRESSURE RELIEF FOR ALT. FORM OF T&P
07/14/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
DWV WATER TEST THRU ROOF OK
WATER DISTRIBUTION OK EXCEPT

1. PROVIDE 18" MINIMUM COPPER PIPING IN WALL AT WATER HEATER
2. 2006 IECC REQUIRES MINIMUM 8' IN AND 8' OUT OF WATER HEATER PIPING TO BE INSULATED
3. INSTALL WATER HAMMER ARRESTORS PER PLAN
4. PROVIDE STAMPED SEALED LETTER FROM ENGINEER OR ARCHITECT GIVING OK TO SUP PEX WATER PIPING FOR T/L COPPER PER PLAN
5. NEED TO SEE CORRECT SHOWER PAN INSTALL AND CLOSET FLANGE AFTER FINISH FLOOR INSTALL