Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T08CM00994
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/22/2008 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
07/16/2008 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. STRAP SER CABLE THROUGH ATTIC SPACE MAX EVERY 54" 2. LOW VOLTAGE AND HIGH VOLTAGE CANNOT BE IN SAME JUNCTION BOX FOR DOORBELL SYSTEM 3. SERVICE NOT PER PLAN NEED APPROVED REVISION TO PLANS 4. INSTALL CONNECTORS ON SER CABLE AT SERVICE EQUIPMENT |