Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T08CM00962
Inspection Description - ROOF NAILING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/28/2008 | ROOF NAILING | Approved | IVRS - Inspection :* 1) WIND BRACE 2ND FLOOR EAST |
|
| 04/23/2008 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ALL SHEAR WALLS REQ. DBL. STUDS AT WALL ENDS. NAIL ALL VENT STUDS ATTACHED TO P.A's & H.D'S 2. #8 STRAPS 1ST 2ND FLR SHEAR LOCATIONS ARE CS16 DBL. STRAPS 3. MISSING WIND BRACE 3RD FLR EAST REAR 4. TIE STUDS TO PLATES AT REAR COLS. 5. FRONT SHEAR AT GARAGE SIDES IS 4" O.C EDGE 6. HANGERS FOR GARAGE HIPS & JACKS OR BACK NAIL INTO GIRDER/REQ'D? 7. TIGHTEN HD8A'S AT GARAGE 8. PULL NAIL AT KIT. 2" ABS DRAIN BOTTOM PLATE 9. USE MINIMUM 16d SINKERS IN CREST 14 3" WIDE STRAPS AT STAIR SHEAR |